Configuring Multiple Nurse Call Connectors

For the configuration of multiple nurse call systems, create multiple copies of the <interface> tag in the nurse call connector configuration file. This is located in <Vocera>\mVisumAlerts\Vocera Nurse Call Connector\Config\Configuration.xml, where <Vocera> is the folder in which you have installed CWE.

The following sample configuration file contains configuration information for two nurse call systems. In each copy, provide different values for the port, name, template, and normalizer parameters.

<?xml version="1.0"?>
<Configuration>
<DataDirectory>
<Value>D:\Projects\NurseCallConnector\NurseCallConnector\Data\</Value>
</DataDirectory>
<interface>
<name>InfinitySim</name>
<serverPort>3100</serverPort>
<NoChecksum>true</NoChecksum>
<NoRcvTimeout>false</NoRcvTimeout>
<NoLogin>false</NoLogin>
<clientsAllowed>127.0.0.1</clientsAllowed>
<template>{$Area(0,0)}{$Room#(0,0)}{$Bed#}{$Event(1,4)}{$Action(0,1)}</template>
<normalizerFilePath>C:\Vocera\mVisumAlerts\Vocera Nurse Call Connector\Config\normalizer-1.xml </normalizerFilePath>
</interface>
<interface>
<name>Rauland</name>
<serverPort>3200</serverPort>
<NoChecksum>true</NoChecksum>
<NoRcvTimeout>false</NoRcvTimeout>
<NoLogin>false</NoLogin>
<clientsAllowed>127.0.0.1</clientsAllowed>
<template>{$Area(0,0)}{$Room#(0,0)}{$Bed#}{$Event(1,4)}{$Action(0,1)}</template>
<normalizerFilePath>C:\Vocera\mVisumAlerts\Vocera Nurse Call Connector\Config\normalizer-2.xml </normalizerFilePath>
</interface>
</Configuration>