Setting up the Vocera Rauland Integration SIP Gateway Server |
Review an example of the RSIP Gateway Server properties file.
If your Vocera system has direct SIP integration with a Nurse Call system (such as Rauland Responder 5), configure the integration using the properties below. RSipIPAddress = The IP address of the Nurse Call system's SIP server. For Rauland Responder 5, enter the Brekeke SIP Server in standard dotted-decimal notation (for example,192.168.15.10). RSipVMIClientID = The client ID used to uniquely identify each RSIP Gateway when VMI messages are sent to the Vocera Server. Note: Use alpha characters only. This value cannot contain backslashes, hyphens, underscores, or apostrophes. RSipVMIResponses = A comma-delimited list containing the text strings used to identify vmi responses, for example, "accept, reject". RSipIPAddress = 10.1.7.32 RSipVMIClientID = RaulandClient RSipVMIResponses = accept, reject